102

Restore Parameters to Default

Kone · Elevator Control

Hva betyr 102 ?

The system indicates that parameters have been restored to their default settings. This is a warning only, potentially indicating an unexpected system reset or user action.

Vanlige årsaker

  • Manual intervention to reset parameters to factory defaults.
  • System anomaly causing an automatic parameter reset.
  • Corrupted parameter memory requiring a restore operation.

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    Verify currently loaded parameters against the elevator's specific configuration documentation.

  2. 2

    Inspect system event logs for entries preceding the parameter restore, such as power loss, watchdog reset, or manual reset commands.

  3. 3

    Measure supply voltage at the control unit's input terminals for stability and adherence to nominal values.

  4. 4

    Check status of internal battery backup (if applicable) for parameter retention and proper charging.