CAPACITOR CHARGE
Kone · Elevator Control
Hva betyr 1060 ?
The motor controller (codes 1060, 2060, 3060) has detected an issue with the capacitor charge process. This typically relates to the DC bus charging circuit during power-up. The specific lift reaction is controller dependent.
Vanlige årsaker
- Failure of pre-charge circuit components (e.g., resistor, relay).
- Excessive resistance in the DC link charging path.
- Faulty DC bus capacitors or voltage measurement circuit.
Reparasjonssteg & Sjekkliste
Klikk på steg for å spore fremgangen.
- 1
Verify incoming AC supply voltage at the motor controller's input terminals against nominal values.
- 2
Inspect all power cabling and connections to the motor controller for looseness, corrosion, or damage, focusing on the main power input and DC bus pre-charge circuit components.
- 3
Measure the DC bus voltage across the appropriate terminals on the motor controller during a power-up attempt to observe the charging process.
- 4
Check the operation and auxiliary contacts of any pre-charge contactors or relays associated with the DC bus charging circuit.
- 5
Verify the motor controller's drive parameters related to power-up, DC bus pre-charge, and undervoltage thresholds against the manufacturer's specifications.