The Lock Drops off in Operation (Emergency Stop)
Kone · Frequency Inverter
Hva betyr 02 ?
This error indicates that the door lock safety circuit is active during lift operation, suggesting a loss of the lock signal even though the safety circuit itself is present. This condition typically triggers an emergency stop of the lift, prioritizing passenger safety.
Vanlige årsaker
- The lock signal is unexpectedly lost while the lift is in operation.
- Intermittent connection or fault within the safety circuit related to the door lock.
- Malfunctioning door lock contacts failing to maintain engagement.
Reparasjonssteg & Sjekkliste
Klikk på steg for å spore fremgangen.
- 1
Inspect the entire safety circuit related to the door lock for any intermittent connections, loose wiring, or damaged components.
- 2
Verify the door lock contacts for proper engagement, ensuring they are clean and free from obstruction.
- 3
Check for any external interferences that might cause momentary disengagement of the door lock signal.
Verifisert teknisk data. Sist oppdatert: March 2026