Oversetter...
0112
Overlapping of switches 61:U and N too small
Kone · V3F25/18 drive
Hva betyr 0112 ?
The shaft setup for the V3F25/18 drive is not completed. This indicates an issue with the physical positioning or alignment of the vanes or magnets and their corresponding switches, leading to insufficient overlap between switches 61:U and N.
Vanlige årsaker
- Vanes or magnets and switches are not positioned according to the shaft vane diagram.
- Vanes are not correctly aligned in accordance to the oscillator reader.
Reparasjonssteg & Sjekkliste
Klikk på steg for å spore fremgangen.
- 1
Check that the vanes or magnets and switches are positioned according to the shaft vane diagram.
- 2
If vanes are present, ensure they are correctly aligned in accordance with the oscillator reader.
- 3
Perform the shaft setup again after vane or magnet/switch adjustment.
Verifisert teknisk data. Sist oppdatert: March 2026
Relaterte feilkoder
Kilde: Kone V3F25/18 drive