Oversetter...
MR11

Alarm Space 11 Violation

Kuka · KK53Y Servo Motor

Hva betyr MR11 ?

The MR11 signal indicates a violation of monitoring space 11. A '0' state on this signal means that monitoring space 11 is currently being infringed upon. If monitoring space 11 is intentionally inactive, the system considers it violated by default, and the associated safe output MR11 will be in the '0' state.

Vanlige årsaker

  • Alarm condition triggered in Space 11 of the monitoring system.
  • Parameter P11 has exceeded its defined alarm threshold.
  • Sensor associated with Space 11 reporting an out-of-bounds value.
  • Configuration error in Space 11 alarm limits.

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    Identify the configured boundaries for monitoring space 11 in the robot's programming environment (e.g., using KUKA WorkVisual).

  2. 2

    Physically inspect the robot's current position and ensure no part of the manipulator, external axes, or tooling is entering or has entered the defined monitoring space 11.

  3. 3

    If monitoring space 11 is intended to be inactive, verify this configuration in WorkVisual and acknowledge that the MR11 signal will default to a '0' (violated) state.

Se alle koder i denne manualen (17)
Verifisert teknisk data. Sist oppdatert: March 2026

Relaterte feilkoder