Ballast switch energized for too long PMx during charging

KPS Ballast Switch Overload During Charging

Kuka · KR C2 Robot Controller

Hva betyr Ballast switch energized for too long PMx during charging ?

The brake resistor experienced an I²t overload during the charging phase. This indicates that the ballast switch was energized for an excessive duration, possibly due to a defective ballast resistor or incorrect connection.

Vanlige årsaker

  • Ballast switch in KPS remains energized for too long during the charging phase.
  • Faulty ballast switch not de-energizing correctly.
  • Control signal for the ballast switch is stuck 'on'.
  • Incorrect timing in the charging sequence.

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    Check the ballast resistor for defects, including open circuits or incorrect resistance values.

  2. 2

    Verify the correct wiring and connection of the ballast resistor to the KPS module.