Brake error Ax/PMx channel x

External Axes Brake Error

Kuka · KR C2 Robot Controller

Hva betyr Brake error Ax/PMx channel x ?

A brake error has occurred on the external axes, specified by channel x. This could be due to the brakes not being connected or a short-circuit present on the brake cable.

Vanlige årsaker

  • External axis brake circuit has an error on channel (x).
  • Mechanical brake failure on the external axis.
  • Wiring or connection issue with the external axis brake actuator.
  • Control signal error for the external axis brake engagement.

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    Verify that the brakes for the specified external axis channel are correctly connected at the KPS and motor.

  2. 2

    Check the brake cable for the external axis channel for any short circuits or damage.