Heat sink temperature PMx
KPS Heat Sink Overtemperature
Kuka · KR C2 Robot Controller
Hva betyr Heat sink temperature PMx ?
An overtemperature condition has been detected on the heat sink of the KPS module (PMx). This indicates that the cabinet ventilation is not functioning correctly, leading to inadequate cooling of the KPS.
Vanlige årsaker
- Ambient temperature in the cabinet is too high.
- Insufficient cooling for the KPS heat sink (blocked vents, fan failure).
- Drive operating at peak load for extended periods.
- Oversized motor or drive operating inefficiently.
- Faulty temperature sensor on the heat sink (P6-01).
Reparasjonssteg & Sjekkliste
Klikk på steg for å spore fremgangen.
- 1
Check the cabinet cooling circuit and fans for proper operation and sufficient airflow.
- 2
Verify that cabinet air filters are clean and not obstructed.
Verifisert teknisk data. Sist oppdatert: March 2026