Intermediate circuit charging circuit defective PMx
KPS Intermediate Circuit Charging Circuit Defective
Kuka · KR C2 Robot Controller
Hva betyr Intermediate circuit charging circuit defective PMx ?
The optocoupler responsible for ballast resistor current detection signals that no current is flowing through the ballast resistor, even during charging. This indicates a defect in the intermediate circuit charging circuit of the KPS module (PMx).
Vanlige årsaker
- KPS intermediate circuit charging circuit is defective.
- Failure within the KPS power supply's charging module.
- Internal component failure affecting the charging circuit's operation.
Reparasjonssteg & Sjekkliste
Klikk på steg for å spore fremgangen.
- 1
Restart the KPS module.
- 2
If the error persists, exchange the KPS module.