26044

Unknown device status, KPP/KSP (axis)

Kuka · KR C4 extended

Hva betyr 26044 ?

The KPP or KSP module for a specific axis is reporting an unknown device status. This indicates an unexpected operational state not recognized by the controller.

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    Measure the DC supply voltage to the affected KPP/KSP module at its input terminals, comparing against specified nominal values.

  2. 2

    Inspect all communication cables (e.g., EtherCAT/X44) connecting the KPP/KSP module to the main controller for secure connections and signs of damage.

  3. 3

    Observe the status LEDs on the affected KPP/KSP module and interpret their state according to the Kuka KR C4 documentation for axis modules.

  4. 4

    Verify the axis configuration parameters and module assignment within the Kuka HMI/WorkVisual software for the specific KPP/KSP module and axis.