Oversetter...
26050

Fault in brake resistor, KPP/KSP (axis)

Kuka · KR C4 extended

Hva betyr 26050 ?

The KPP module has detected an error in the ballast circuit, which typically includes the brake resistor. This indicates an issue with the energy dissipation components, potentially leading to overvoltage conditions if braking energy cannot be properly absorbed.

Vanlige årsaker

  • Ballast resistor fault.
  • Cabling between KPP and ballast resistor is damaged or improperly connected.

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    Inspect the ballast resistor for damage or overheating.

  2. 2

    Check cabling between the KPP and the ballast resistor for damage and correct connections.

  3. 3

    Reinitialize the drive bus: Power Off / Power On.

  4. 4

    Check the KPP module.

Se alle koder i denne manualen (35)
Verifisert teknisk data. Sist oppdatert: March 2026

Relaterte feilkoder

Kuka 26050 support: Fault in brake resistor, KPP/KSP (axis)… | ErrorLib