Oversetter...
26034

Overcurrent, KPP/KSP (axis)

Kuka · KR C4 Operating Instructions

Hva betyr 26034 ?

A fault has briefly resulted in an overcurrent that exceeds the maximum current rating of the KPP, such as a short-circuit. This indicates an immediate and severe current surge within the motor circuit, potentially causing component damage.

Vanlige årsaker

  • Excessive current detected in the KPP/KSP drive output stage.
  • Motor is drawing more current than the drive can supply.
  • Short circuit in the motor, motor cable, or drive output.
  • Mechanical binding or jamming of the axis.
  • Overload condition during acceleration or deceleration.

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    Review the trace recording of the axis/current to pinpoint the exact timing and magnitude of the overcurrent event.

  2. 2

    Check the motor for any short circuits, winding damage, or mechanical binding causing excessive current draw.

  3. 3

    Check the motor cable for shorts between phases or to ground using a multimeter.

  4. 4

    Reinitialize the drive bus by performing a Power Off / Power On cycle of the entire system.

  5. 5

    Check the KSP module for diagnostic indicators related to overcurrent protection.

  6. 6

    Check the KPP module for diagnostic indicators related to overcurrent protection.

Se alle koder i denne manualen (22)
Verifisert teknisk data. Sist oppdatert: March 2026

Relaterte feilkoder

Kilde: Kuka KR C4 Operating Instructions