Stop Due to Field Bus Error
Kuka · KR C4 PROFIBUS
Hva betyr 2858 ?
The robot controller has entered a stop state because an error occurred on the field bus. This indicates a general issue preventing normal operation over the PROFIBUS.
Vanlige årsaker
- Loss of communication with a critical field bus device (e.g., I/O module, drive).
- Network congestion or packet loss on the field bus.
- Incorrect or missing configuration of a field bus node.
- Physical damage to the field bus cabling or connectors.
Reparasjonssteg & Sjekkliste
Klikk på steg for å spore fremgangen.
- 1
Verify the status LED on each field bus node is illuminated green.
- 2
Inspect the field bus cable integrity from the controller to the furthest node.
- 3
Check the field bus termination resistors at both ends of the bus.
- 4
Review the field bus configuration parameters in the controller, specifically the node addresses.
- 5
Measure the signal amplitude on the field bus data lines.