invalid Gateway Error-Byte Config
Invalid Gateway Error-Byte Configuration
Kuka · KR C4 PROFIBUS
Hva betyr invalid Gateway Error-Byte Config ?
The configuration of the error status bytes for the devices does not match the overall bus configuration. This suggests a mismatch in how error conditions are reported or interpreted.
Vanlige årsaker
- Error-byte configuration in the gateway is invalid or not supported.
- Incorrect bitmask or value set for error reporting in the gateway.
- Firmware mismatch between gateway and configuration tool.
- Attempting to configure error reporting beyond device capabilities.
Reparasjonssteg & Sjekkliste
Klikk på steg for å spore fremgangen.
- 1
Check the bus configuration in WorkVisual for consistency in error byte settings and correct if necessary.
- 2
Reconfigure the bus after correcting the configuration.
Verifisert teknisk data. Sist oppdatert: March 2026