Hva betyr 123 ?

The internal servo output stage is not ready due to an undervoltage condition. This will cause maximum braking and inhibit all active commands.

Vanlige årsaker

  • Supply voltage dropped below the minimum threshold (e.g., P1-01).
  • Power supply unit failure.
  • Loose electrical connection on the power input terminals.
  • Overload condition drawing excessive current, causing voltage sag.

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    Rectify the undervoltage fault condition.

  2. 2

    Reset the fault by pressing the hardware acknowledgement button 'ACK' on the DSE I module.