Error safety loop

Kuka · KRC2 KSS System Message

Hva betyr 13 ?

A channel in the safety loop has failed, or more than one enabling switch has been pressed simultaneously. This will cause path-maintaining braking and inhibit all active commands.

Vanlige årsaker

  • The safety loop has detected an error condition.
  • Interruption or fault in the physical safety circuit (e.g., emergency stop button, safety gate).
  • Safety device triggered or malfunctioning.

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    Eliminate the fault condition within the safety loop circuitry.

  2. 2

    Ensure that only one enabling switch is pressed at a time during operation.