26024

Max. following error exceeded ({Drive})

Kuka · KSS 8.3 Operating & Programming Manual

Hva betyr 26024 ?

The deviation between the commanded position and the actual position for the specified drive ({Drive}) has exceeded the maximum allowable limit. This often occurs in torque mode operations if regular monitoring functions are not appropriately deactivated, or due to external mechanical resistance.

Vanlige årsaker

  • Excessive deviation between commanded and actual position for the specified drive ({Drive})
  • Regular monitoring functions remaining active during torque mode operations when they should be deactivated
  • Mechanical load or obstruction on the specified drive ({Drive}) preventing accurate positioning

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    If torque mode is intentionally active, verify that regular monitoring functions are deactivated using SET_TORQUE_LIMITS(..., monitor #off)

  2. 2

    Investigate mechanical load or obstruction on the specified drive ({Drive}) that might be causing position deviation

  3. 3

    Check for correct tuning of the drive's position control loop