PWR_+12V5 Off

Brake Chopper Power Supply Not Present

Kuka · Sunrise Cabinet Med Controller

Hva betyr PWR_+12V5 Off ?

The PWR_+12V5 Green LED is OFF, indicating that the brake chopper power supply is not present. This condition means the 12.5V power rail required for the brake chopper operation is missing, which could impact the robot's ability to dissipate regenerative energy during braking. Without this power, the brake chopper cannot function.

Vanlige årsaker

  • The +12.5V power supply to the brake chopper circuit is not present.
  • No voltage detected on the +12.5V line supplying the brake chopper.
  • Failure in the power source for the brake chopper control (e.g., fuse, regulator).

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    Check the integrity and ensure proper seating of connector X500.

  2. 2

    Check the connector on the low-voltage power supply unit for proper connection and any visible damage.