CE0
Automation interface (AIF) communication error
Lenze · 9300 Series
Hva betyr CE0 ?
Faulty transfer of control commands has occurred via the Automation Interface (AIF). This is often due to a loose communication module or keypad XT connection, disrupting essential command signals.
Vanlige årsaker
- Loss of communication with the Automation Interface (AIF) module.
- Faulty AIF module hardware.
- Incorrect AIF module configuration or addressing.
- Interference on the communication bus used by AIF.
Reparasjonssteg & Sjekkliste
Klikk på steg for å spore fremgangen.
- 1
Plug in the communication module/keypad XT firmly and screw it down, if necessary.
- 2
Switch off monitoring by setting C0126 = 3.