P19

Input values at X9 are limited

Lenze · 9300 Series

Hva betyr P19 ?

The function block DFIN is limiting the input values at X9, which causes a loss of increments. This suggests an issue with the digital frequency connection or a mismatch in master/slave settings, affecting precise control.

Vanlige årsaker

  • Digital frequency input (DFIN) parameters (e.g., P1-60 to P1-63) are configured to limit the input frequency or pulse count received at X9.
  • The frequency signal applied to X9 exceeds the maximum permissible input frequency defined by DFIN scaling parameters.
  • Mismatch between the master encoder output frequency and the slave device's DFIN input scaling, causing saturation or clipping.
  • Noise or signal integrity issues on the digital frequency input lines at X9, leading to misinterpretation of high frequency pulses.
  • Incorrectly set filter parameters (e.g., P1-64) for the DFIN input at X9, causing signal attenuation at higher frequencies.

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    Review parameters P1-60 (DFIN scaling) and P1-61 (DFIN maximum input frequency) to ensure they match the expected input signal range.

  2. 2

    Using an oscilloscope, measure the actual frequency and amplitude of the signal applied to X9 to ensure it's within expected limits.

  3. 3

    Adjust the master device's output frequency or the slave device's DFIN scaling parameters (P1-60 to P1-63) to prevent exceeding limits.

  4. 4

    Verify the integrity of the cabling to X9 for proper shielding and termination to minimize noise, especially for high-frequency signals.

  5. 5

    Temporarily disable or adjust any active filters (e.g., P1-64) on the DFIN input to see if they are causing unintended signal limitation.

  6. 6

    Check for any internal function block logic (e.g., via diagnostic software) that might be imposing additional limits on the DFIN value after scaling.