Oversetter...
0x63A2

PU: load error ID tag

Lenze · i550 Protec Drive

Hva betyr 0x63A2 ?

This fault indicates that the calibration data of the power unit (PU) is either incompatible or faulty. This leads to immediate inverter disablement and motor coasting, and requires a mains power cycle to reset.

Vanlige årsaker

  • Incompatible power unit (PU) installed in the inverter, not matching the control unit's expected ID tag or rating.
  • Corruption of the power unit's internal memory where calibration data (ID tag) is stored.
  • Physical damage or electronic failure of the power unit hardware (e.g., internal communication board).
  • Firmware mismatch between the control unit (CU) and the power unit (PU), preventing proper communication and identification.
  • Poor electrical connection between the control unit and the power unit.

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    Perform a complete mains power cycle of the inverter (disconnect and reconnect the main supply) as specifically indicated by the fault description.

  2. 2

    Verify that the power unit (PU) and control unit (CU) are correctly matched in terms of model, rating, and compatibility according to the manufacturer's documentation.

  3. 3

    Visually inspect all connections between the control unit and power unit for proper seating, physical damage, or corrosion.

  4. 4

    If possible, attempt to re-establish communication or re-initialize the power unit's ID tag through a specific diagnostic function in the inverter's menu.

  5. 5

    If the fault persists after these steps, replacement of the power unit (PU) with a compatible and correctly sized spare is likely required.

Se alle koder i denne manualen (52)
Verifisert teknisk data. Sist oppdatert: March 2026

Relaterte feilkoder