Hva betyr E.PE2 ?

This internal board fault trips the inverter when there is an incorrect combination or mismatch between the control board and the main circuit board. This indicates a serious hardware incompatibility or assembly error. The inverter cannot operate safely under these conditions.

Vanlige årsaker

  • Control circuit board installed is not compatible with the main power circuit board (e.g., different generations or power ratings).
  • Incorrect firmware loaded onto the control board for the specific main circuit hardware configuration.
  • Loose or damaged connection ribbon cable between the control board and the main power board.
  • Internal component failure on either the control board or main power board causing an incompatibility detection.

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    Verify part numbers and serial numbers of both the control board and the main power board against inverter documentation for compatibility.

  2. 2

    Power down the inverter, then physically disconnect and reconnect the ribbon cable(s) that link the control board to the main power board.

  3. 3

    Check for any bent pins or damage on the connectors of the ribbon cables and the board interfaces.

  4. 4

    Confirm that the firmware version on the control board is the correct one for the installed main power section.

  5. 5

    Measure resistance between communication lines on the ribbon cable to identify any broken traces or short circuits.