E51

Power Transistor Overheat

Mitsubishi Electric · FR-D700 Inverter

Hva betyr E51 ?

The power transistor has overheated, indicating excessive heat generation, potentially due to a fault or overload condition. This protects the inverter from damage.

Vanlige årsaker

  • Overheating of the inverter's power transistors due to insufficient cooling.
  • Excessive current draw through the power transistors.
  • Faulty heatsink thermal paste or inadequate fan operation for the inverter.
  • Short-term overload condition during motor startup.

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    Inspect the inverter unit's heatsink for dust accumulation and ensure proper ventilation clearances.

  2. 2

    Verify the outdoor fan operation is providing adequate cooling to the inverter components, checking fan speed and direction.

  3. 3

    Measure the current draw of the compressor and compare to specification, checking for overload conditions.

  4. 4

    Check for loose electrical connections within the inverter module's power circuit.

Se alle koder i denne manualen (78)
Verifisert teknisk data. Sist oppdatert: March 2026

Relaterte feilkoder

Kilde: Mitsubishi Electric FR-D700 Inverter