Oversetter...
1BF0H

Auxiliary Shaft Servo Input Axis Conflicts with Output Axis

Mitsubishi Electric · MELSEC iQ-R Motion Controller

Hva betyr 1BF0H ?

This minor error occurs when the servo input axis number (1 to 64) specified in [Pr.418] for the auxiliary shaft is set to the same value as an output axis. This conflict prevents the initiation of synchronous control, as the system cannot properly assign input and output roles for the conflicting axis ID.

Vanlige årsaker

  • The servo input axis number (1 to 64) set in "[Pr.418] Auxiliary shaft axis No." duplicates an existing output axis number in the system configuration.

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    Verify the value of "[Pr.418] Auxiliary shaft axis No." for the auxiliary shaft, ensuring it is within the valid range (1-64 for servo input axis).

  2. 2

    Check the servo network settings to identify all numbers currently assigned to output axes.

  3. 3

    Modify the setting of "[Pr.418] Auxiliary shaft axis No." to a unique axis number that does not correspond to any configured output axis.

Se alle koder i denne manualen (19)
Verifisert teknisk data. Sist oppdatert: March 2026

Relaterte feilkoder

Kilde: Mitsubishi Electric MELSEC iQ-R Motion Controller