0x4101 to 0x42FF

FAL(006) Error

Omron · CJ-series CJ2 CPU Unit

Hva betyr 0x4101 to 0x42FF ?

The Function Advance Logic (FAL) instruction number 006 has been executed in the program. This indicates a user-defined error condition has been met. The specific FAL number (001 to 511) is stored in Auxiliary Area A400 (leftmost digit 4, rightmost 3 digits 101 to 2FF hex) and flags A360 to A391.

Vanlige årsaker

  • User-defined error condition detected and triggered by the FAL(006) instruction in the PLC program.

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    Correct the PLC program logic according to the specific cause indicated by the FAL number stored in Auxiliary Area A400 and flags A360 to A391 (set by the user).