18230000

Absolute Encoder Multi-rotation Counter Error

Omron · NJ/NX-series Machine Automation Controller

Hva betyr 18230000 ?

The absolute encoder's multi-rotation counter detected an error, indicating a discrepancy in its tracking of motor rotations. This can be caused by environmental factors or an internal encoder malfunction.

Vanlige årsaker

  • Temporary error in encoder multi-rotation detection function due to vibration
  • Temporary error in encoder multi-rotation detection function due to impact
  • Temporary error in encoder multi-rotation detection function due to condensation
  • Absolute encoder hardware failure

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    Inspect the encoder mounting for excessive vibration or impact.

  2. 2

    Check for signs of condensation or moisture near the encoder.

  3. 3

    Verify the encoder's operational environment against specifications.