Oversetter...
408

PCU CEMF FAULT

Otis · DSD 412 DC Elevator Drive

Hva betyr 408 ?

The Counter Electromotive Force (CEMF) of the motor exceeded 118% of the rated AC voltage to the drive. This fault indicates a miss-operation causing speed overshoot. This fault causes a drive shutdown to prevent fuse blowing.

Vanlige årsaker

  • 3 Phase Input AC Line Voltage is low.
  • Incorrect motor field current setting or field regulator causing excessive CEMF.
  • Excessive drive speed causing overshoot.
  • Incorrect motor field control dynamic tuning adjustments.

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    Check and correct the 3 Phase Input AC Line Voltage.

  2. 2

    Adjust velocity regulator tuning to prevent CEMF overshoot.

  3. 3

    Review and verify settings for parameters #49, #50, #51, #52, #54, and #55.

  4. 4

    Check and correct motor field control dynamic tuning to prevent overshoot.

Se alle koder i denne manualen (48)
Verifisert teknisk data. Sist oppdatert: March 2026

Relaterte feilkoder

Kilde: Otis DSD 412 DC Elevator Drive