409

UNEXPECTED PCU RESET

Otis · DSD 412 Elevator System

Hva betyr 409 ?

The PCU processor was unexpectedly reset.

Vanlige årsaker

  • Incorrect PCU software and revision level.
  • Problem with main circuit card hardware.
  • External noise interference.
  • Improper equipment and signal grounding connections.

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    Verify that the correct PCU software and revision level are being used.

  2. 2

    Inspect for external noise interference sources.

  3. 3

    Ensure equipment and signal grounding connections are proper.

  4. 4

    If the problem remains, replace the Drive Control PCB.

Se alle koder i denne manualen (57)