Oversetter...
>ACS is on !
Anti Creeping Switch Operated
Otis · GAA21750AK3 Service Tool
Hva betyr >ACS is on ! ?
This blinking event message indicates that the Anti Creeping Switch (ACS) is in an operated state, which has blocked the elevator. The ACS is a safety device designed to prevent unintended movement of the car when it is at a landing.
Vanlige årsaker
- Mechanical actuation of the Anti Creeping Switch due to minor car movement or incorrect leveling.
- Faulty Anti Creeping Switch wiring or internal failure.
- Misalignment of the ACS triggering mechanism.
Reparasjonssteg & Sjekkliste
Klikk på steg for å spore fremgangen.
- 1
Verify the elevator car is correctly leveled at the landing.
- 2
Inspect the Anti Creeping Switch (ACS) for mechanical damage, obstruction, or misalignment.
- 3
Check the wiring to the ACS for continuity and secure connections.
- 4
Measure the state of the ACS contact using a multimeter to confirm open/closed status.
Verifisert teknisk data. Sist oppdatert: March 2026
Relaterte feilkoder
Kilde: Otis GAA21750AK3 Service Tool