Position error

DCS Position Error

Otis · GAA21750AK3 Service Tool

Hva betyr Position error ?

A discrepancy in the elevator car's position was detected during the Door Check Sequence (DCS) at a specific level. This error indicates that the LCB_II control system's perceived car position does not match the actual physical position, affecting safety and sequence execution for the OTIS 2000 Controllers MCS120/MCS220.

Vanlige årsaker

  • Faulty or misaligned position sensors (e.g., encoder, absolute position device).
  • Issues with hoistway limit switches or their associated circuits.
  • Incorrectly set position reference parameters.
  • Slippage in the traction system affecting position feedback.

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    Identify the specific level where the position error occurred from the GAA21750AK3 service tool.

  2. 2

    Verify the calibration and functionality of the elevator's position sensors.

  3. 3

    Inspect all hoistway limit switches for proper mechanical actuation and electrical integrity.

  4. 4

    Check relevant position-related parameters for correct configuration within the service tool. Perform a hoistway learning or re-leveling sequence if applicable.

Se alle koder i denne manualen (15)