Oversetter...
EPH1
Input Phase Loss Fault
Schindler · Altivar 212 Variable Frequency Drive
Hva betyr EPH1 ?
This fault occurs when one or more input phases to the Altivar 212 drive are lost, indicating an issue with the incoming AC supply or its connection to the drive.
Vanlige årsaker
- Loss of one or more input phases.
- Incorrect setting of parameter F608 ([Input phase loss]).
Reparasjonssteg & Sjekkliste
Klikk på steg for å spore fremgangen.
- 1
Measure the incoming AC line voltage at the drive input terminals (R/L1, S/L2, T/L3) to confirm phase presence.
- 2
Check upstream circuit breakers or contactors for proper operation and continuity.
- 3
Verify the setting of parameter F608 ([Input phase loss]) to ensure it is appropriate for the application.
Verifisert teknisk data. Sist oppdatert: March 2026
Relaterte feilkoder
Kilde: Schindler Altivar 212 Variable Frequency Drive