M020

Total Input Power Exceeded

Schindler · Altivar 212 Variable Frequency Drive

Hva betyr M020 ?

This fault occurs when the accumulated input power value, typically measured in kWh, exceeds the maximum displayable value of 999.999 kWh, indicating a data overflow.

Vanlige årsaker

  • Accumulated input power value has exceeded 999.999 kWh.

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    Clear the accumulated input power value using logic input function 51 (Reset kWh).

  2. 2

    Alternatively, clear the accumulated input power value by setting parameter F748 ([Power cons. memo]) to 0 (Disable) and then cycling power to the drive.