Oversetter...
F38

AI L2 Under Voltage

Schneider Electric · XW Pro NA Operation Guide

Hva betyr F38 ?

This fault indicates an L2 under-voltage condition (66 VAC) detected by the anti-islanding protection, triggering a fast disconnect. This mechanism ensures the inverter disconnects from an unstable grid, protecting both the inverter and grid from potential damage due to critically low voltage.

Vanlige årsaker

  • Severe and sudden drop in L2-Neutral grid voltage below 66 VAC, indicating a local grid fault, near short-circuit, or complete phase loss.
  • Major power system event causing an immediate and critical voltage sag or collapse on phase L2.
  • Inverter's L2 voltage sensing circuit experiencing a catastrophic failure or complete loss of signal, leading to an immediate trip.
  • Anti-islanding parameter P_AI_L2_Volt_Min_Fast set too restrictively, triggering a fast disconnect even on momentary deep sags.

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    Immediately verify the L2-Neutral voltage at the inverter's AC input terminal L2 using a true RMS multimeter to confirm grid voltage presence.

  2. 2

    Check the utility main breaker or local upstream breaker supplying the inverter for a tripped condition, indicating a severe electrical fault.

  3. 3

    Inspect the physical wiring connections for the L2 phase and neutral (Terminal L2, Terminal N) at the inverter and upstream disconnects for obvious damage or complete disconnection.

  4. 4

    Review the inverter's event log to determine if the voltage drop was sudden and severe, or if other phases were affected simultaneously.

  5. 5

    If all external power and wiring appear correct and the grid is stable, the inverter's internal L2 fast voltage sensing circuit may be faulty, requiring service.

Se alle koder i denne manualen (60)
Verifisert teknisk data. Sist oppdatert: March 2026

Relaterte feilkoder

Kilde: Schneider Electric XW Pro NA Operation Guide