90
Incorrect Motor/Inverter Assignment
SEW Eurodrive · MOVIMOT® MM..D with AC Motor DT/DV / Operating Instruc
Hva betyr 90 ?
This fault indicates that the parameters configured for the motor do not correctly match the assigned inverter power, or vice versa. This mismatch can lead to improper motor control, reduced performance, or damage to both motor and inverter.
Vanlige årsaker
- Incorrect assignment of motor type to the frequency inverter.
Reparasjonssteg & Sjekkliste
Klikk på steg for å spore fremgangen.
- 1
Verify the correct motor parameters are assigned within the inverter's configuration.
- 2
Check the combination of the drive (motor) and MOVIMOT inverter against technical specifications.
- 3
Reset the fault by switching off and then switching on the DC 24V supply voltage.
- 4
Reset the error via the error reset function.