09

Startup error

SEW Eurodrive · Drives

Hva betyr 09 ?

A startup error has occurred, indicating that certain additional functions are not permitted in the current configuration. Specifically, additional functions 4, 5, or 12, controlled by DIP switches S2/5 through S2/8, are active but are not allowed.

Vanlige årsaker

  • Additional function 4 (DIP switches S2/5-S2/8 configuration) is active but not permitted
  • Additional function 5 (DIP switches S2/5-S2/8 configuration) is active but not permitted
  • Additional function 12 (DIP switches S2/5-S2/8 configuration) is active but not permitted

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    Check the settings of DIP switches S2/5 to S2/8 on the MOVIMOT inverter

  2. 2

    Verify that additional functions 4, 5, and 12 are disabled if they are not permitted for the current startup mode