Oversetter...
25
EEPROM error
SEW Eurodrive · Drives
Hva betyr 25 ?
An error occurred while accessing the internal EEPROM of the MOVIMOT® inverter, potentially indicating data corruption or a defective memory chip. This can affect stored parameters and operational settings.
Vanlige årsaker
- Error during read/write access to the internal EEPROM.
- Defective EEPROM component.
Reparasjonssteg & Sjekkliste
Klikk på steg for å spore fremgangen.
- 1
Set parameter P802 to 'Delivery state' (factory defaults) to reset EEPROM contents.
- 2
Reset the error and then re-parameterize the MOVIMOT® inverter with application-specific settings.
- 3
If the error reoccurs after re-parameterization, contact SEW Service.
Verifisert teknisk data. Sist oppdatert: March 2026
Relaterte feilkoder
Kilde: SEW Eurodrive Drives