Oversetter...
90

Incorrect motor/inverter assignment

SEW Eurodrive · Drives

Hva betyr 90 ?

A mismatch has been detected between the assigned motor type and the MOVIMOT inverter. This indicates that the connected motor is incompatible with the inverter's configuration or capabilities.

Vanlige årsaker

  • Incompatible motor connected to the MOVIMOT inverter
  • Incorrect motor type selection or parameterization in the drive settings

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    Verify the installed motor's nameplate data (e.g., model, power, voltage, current) against the MOVIMOT inverter's specified motor compatibility list and the intended motor assignment.

  2. 2

    Check and confirm all motor-specific parameters (e.g., nominal voltage, current, frequency, RPM, motor type selection) configured within the MOVIMOT inverter's software or HMI against the connected motor's nameplate.

  3. 3

    Inspect the physical wiring connections between the MOVIMOT inverter and the motor for correct phase assignment, secure termination, and any signs of damage or loose contacts that could affect motor identification.

  4. 4

    Verify the MOVIMOT inverter's model number and firmware version are appropriate for the connected motor type and application, referencing official SEW Eurodrive documentation.

Se alle koder i denne manualen (39)
Verifisert teknisk data. Sist oppdatert: March 2026

Relaterte feilkoder