Oversetter...
0012

Read access only

SEW Eurodrive · MOVIDRIVE compact System (MCF/MCV/MCS4_A)

Hva betyr 0012 ?

This PROFIBUS-DP additional code (Error Class 8, 'Other Error') occurs when an attempt was made to write to a parameter via PROFIBUS-DP that is designated as read-only. The inverter rejects the write request for parameters that cannot be modified.

Vanlige årsaker

  • Attempting to write a value to a parameter that is configured for read-only access.
  • Security setting prevents modification of this specific parameter.
  • Parameter is dynamically set and cannot be manually overwritten.

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    Check bits 0 and 1 in the PROFIBUS-DP parameter channel to ensure correct service code and length specification in the telegram.

Se alle koder i denne manualen (78)
Verifisert teknisk data. Sist oppdatert: March 2026