001D
Invalid value for parameter
SEW Eurodrive · MOVIDRIVE compact System (MCF/MCV/MCS4_A)
Hva betyr 001D ?
This PROFIBUS-DP additional code (Error Class 8, 'Other Error') indicates the value supplied for a parameter setting is logically invalid, even if it numerically falls within the acceptable range. This suggests a mismatch with the parameter's expected states or enumerations.
Vanlige årsaker
- The provided value does not conform to the expected format or data type for the parameter.
- The value is logically invalid for the parameter's function (e.g., negative speed command).
- A checksum or CRC error associated with the parameter value.
Reparasjonssteg & Sjekkliste
Klikk på steg for å spore fremgangen.
- 1
Check bits 0 and 1 in the PROFIBUS-DP parameter channel to ensure correct service code and length specification in the telegram.