DC Link Overvoltage
SEW Eurodrive · MOVIDRIVE compact System (MCF/MCV/MCS4_A)
Hva betyr 07 ?
Immediate switch-off triggered when the DC link voltage exceeds its maximum permissible limit. This is often caused by excessive regenerative energy from the motor during deceleration or potentially a ground fault, risking damage to inverter components.
Vanlige årsaker
- DC link voltage within the inverter is too high (e.g., above P4-OV).
- Excessive regenerative energy from the motor causing voltage rise.
- Malfunction in the inverter's DC bus control or braking system.
Reparasjonssteg & Sjekkliste
Klikk på steg for å spore fremgangen.
- 1
Extend the deceleration ramps (e.g., in parameters P501 or P503) to reduce regenerative energy.
- 2
Check the supply cable connections to the braking resistor.
- 3
Verify the technical data (e.g., resistance value) of the braking resistor matches specifications.
- 4
Check for a ground fault in the system.
Verifisert teknisk data. Sist oppdatert: March 2026