Plausibility fault in encoder interface (A3401 = encoder 1 and A3402 = encoder 2)
SEW Eurodrive · MOVIDRIVE MDX60B/61B Variable Speed Drive
Hva betyr F109-44 ?
The encoder interface (A3401 or A3402) does not match the configured data. This suggests a mismatch between the physical encoder type/connection and the drive's settings.
Vanlige årsaker
- Encoder data stream indicates a deviation from expected patterns.
- Mismatch in position or velocity feedback from encoder 1 (A3401) or encoder 2 (A3402).
- Faulty encoder communication protocol interpretation.
- Environmental interference corrupting encoder signals.
Reparasjonssteg & Sjekkliste
Klikk på steg for å spore fremgangen.
- 1
Check encoder type and configuration (SSI/incremental).
- 2
Check the encoder connection/wiring.
- 3
Check the polarity of the encoder data.
- 4
Check function of the encoder.