F109-72
Faulty switching behavior of the high-side driver DO1_P
SEW Eurodrive · MOVIDRIVE MDX60B/61B Variable Speed Drive
Hva betyr F109-72 ?
A DC 24 V short circuit has been detected at the digital output DO1_P (X82:3) from the high-side driver. This indicates an electrical fault on the output channel.
Vanlige årsaker
- High-side driver for digital output DO1_P is not switching correctly.
- Overload condition or short circuit on DO1_P output.
- Failure of the DO1_P output driver circuit.
- Software command for DO1_P switching is erroneous.
Reparasjonssteg & Sjekkliste
Klikk på steg for å spore fremgangen.
- 1
Check wiring at digital output DO1_P (X82:3).