01
Overcurrent in output stage
SEW Eurodrive · MOVIFIT-FC Inverter
Hva betyr 01 ?
This fault indicates an overcurrent condition on the inverter output. It is typically caused by a short circuit in the connection between the inverter and the motor, or a short circuit within the motor winding itself. Excessive current flow from the inverter can lead to damage if not addressed.
Vanlige årsaker
- Motor drawing excessive current exceeding output stage limits.
- Short circuit in motor windings.
- Incorrect motor tuning parameters (e.g., P0307, P0311).
- Mechanical overload or jamming of the driven equipment.
- Output stage power components failure.
Reparasjonssteg & Sjekkliste
Klikk på steg for å spore fremgangen.
- 1
Check the connection between the inverter output and the motor for short circuits.
- 2
Check the motor winding for short circuits.
- 3
Reset the fault by switching off the DC 24 V supply voltage.
Verifisert teknisk data. Sist oppdatert: March 2026