Oversetter...
201673

SI Motion: Sensor Module software/hardware incompatible

Siemens · DAsl Diagnostics and Alarms

Hva betyr 201673 ?

The Sensor Module's existing software and/or hardware is not compatible with the higher-level control's safe motion monitoring function. This prevents the safe motion monitoring features from functioning correctly, potentially impacting safety-critical operations. Note that this specific fault does not immediately result in a safety stop response.

Vanlige årsaker

  • Firmware version of the Sensor Module is incompatible with the safety firmware of the higher-level control unit (e.g., CU320-2, SIMOTION D).
  • Hardware revision mismatch between the Sensor Module and the safety control, requiring an upgrade or downgrade.
  • Incorrect order number for the Sensor Module for the specific safety application (e.g., safe encoder type).
  • Project configuration in TIA Portal or STARTER specifies an incompatible Sensor Module version.

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    Compare the installed firmware version of the Sensor Module with the required version for the safety control unit.

  2. 2

    Update the Sensor Module firmware to a compatible version using STARTER or TIA Portal software.

  3. 3

    Verify the hardware revision number of the Sensor Module and confirm its compatibility with the overall safety system documentation.

  4. 4

    Check the order number (MLFB) of the Sensor Module against the project design specifications.

  5. 5

    Re-compile and download the safety program to the control unit after ensuring compatible module versions are configured.

Se alle koder i denne manualen (31)
Verifisert teknisk data. Sist oppdatert: March 2026

Relaterte feilkoder

Kilde: Siemens DAsl Diagnostics and Alarms