61426

Sum of the active offsets does not equal zero

Siemens · FC1765DC Controller

Hva betyr 61426 ?

This alarm indicates that the sum of active offsets in geometry axes, fine offsets, or rotary components does not equal zero, leading to an inconsistency in the machine's positional calculations. Specific error codes (A-E) identify the type of offset problem (translatory, fine, or rotary for different axes). If not resolved, this can lead to incorrect machine movements, inaccurate positioning, and potentially damage to the workpiece or machine.

Vanlige årsaker

  • Inaccurate or incorrectly defined machine data (MD) for geometry axes or kinematic transformations where offsets are applied.
  • Manual entry errors or incorrect calculation in user-defined fine offsets, workpiece offsets, or rotary component offsets.
  • Corruption of non-volatile memory storing kinematic offset data (e.g., due to power loss, improper shutdown, or hardware issue).
  • Software bug or unexpected behavior in the NC (Numerical Control) system's offset management or transformation calculations.
  • Inconsistent activation or deactivation of coordinate systems or tool offsets leading to an unbalanced sum of active offsets.

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    1. Review all active geometry offsets, fine offsets, and rotary component offsets using the machine's display screens or relevant MD parameters.

  2. 2

    2. Re-enter and meticulously verify the values for all pertinent offset machine data, ensuring they sum to zero as required by the kinematic model.

  3. 3

    3. Perform a system reset (e.g., NC reset, power cycle of the control system) to clear any temporary calculation inconsistencies.

  4. 4

    4. Check for any recent changes to machine data (MDs) related to kinematics or coordinate transformations and revert if unauthorized or incorrect.

  5. 5

    5. If applicable, re-calibrate the machine's kinematic chain or execute a reference point approach (e.g., G74, G75) to re-establish a consistent base.