Oversetter...
C01799

Acceptance test mode active

Siemens · SINAMICS G120

Hva betyr C01799 ?

The acceptance test mode is currently active, indicating that safety functions are being validated. This is a normal state during commissioning or re-validation of safety parameters and functions.

Vanlige årsaker

  • Commissioning engineer explicitly activated acceptance test mode via control panel or engineering software (e.g., Safety Integrated Commander).
  • Safety parameters (e.g., P30600, P30601) were modified, requiring re-validation of safety functions.
  • Initial power-up or system reset after a major configuration change or firmware update.
  • Completion of a mandatory safety documentation procedure for machine validation.

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    Confirm the acceptance test mode activation status on the HMI or drive display (r2124).

  2. 2

    Follow the acceptance test procedure specified in the machine's safety documentation or commissioning manual.

  3. 3

    Deactivate acceptance test mode via control word (e.g., Profisafe telegram bit or P30999) once validation is complete.

  4. 4

    Ensure all safety functions (e.g., STO, SS1, SLS) pass their respective validation steps and document results.

Se alle koder i denne manualen (109)
Verifisert teknisk data. Sist oppdatert: March 2026

Relaterte feilkoder