Oversetter...
59

Follower Communication Break

Vacon · NX Liquid-Cooled Drive

Hva betyr 59 ?

The SystemBus or CAN communication link between the Master and Follower units in a multi-drive system is broken. This interruption prevents synchronized operation and data exchange between the connected drives.

Vanlige årsaker

  • Communication break with a follower device or module.
  • Follower device offline or unresponsive.
  • Communication network issue between devices.

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    Check the option board parameters related to SystemBus or CAN communication for correct configuration (e.g., node IDs, baud rates, communication protocols).

  2. 2

    Inspect the optical fibre cable (for SystemBus) or CAN cable (for CAN communication) for any physical damage, breaks, or loose connections.

Se alle koder i denne manualen (52)
Verifisert teknisk data. Sist oppdatert: March 2026

Relaterte feilkoder