4313
Motor 2 Temperature Alarm Limit Exceeded
ABB · ACS560 Standard Control Program Firmware
What does 4313 mean?
The measured temperature of motor 2 has exceeded the alarm limit defined by parameter 35.05. This indicates a potential overheating situation specific to this motor, which can lead to insulation degradation and reduced motor lifespan if not addressed.
Complete Troubleshooting Guide
- 1
Check and adjust the alarm limit value in parameter 35.05 if it's incorrectly set or too low for the application.
- 2
Verify that the actual number of temperature sensors corresponds to the value set in parameters (e.g., if using multiple sensors).
- 3
Allow the motor to cool down by reducing load or stopping operation.
- 4
Ensure proper motor cooling by checking the motor's cooling fan and cleaning cooling surfaces or air passages.