Warning during parameter application (_ecPARAM_APPLICATION_WARNING)
ABB · ACS850 Standard Program Firmware
What does 225 mean?
This is a warning during parameter application to an e100 drive, often due to an unsupported parameter, an incorrect number of arguments/values, wrong value types, or attempting to download a parameter table from a different product configuration (e.g., a resolver option table to a non-resolver drive). While a warning, it means parameters may not be correctly applied, leading to suboptimal or incorrect drive operation.
Additional Steps
Steps 1–2 are listed in Priority Fix.
- 3
Verify that the argument list has the correct number of parameters and that the data types of values are correct.
- 4
Confirm that the parameter table was generated for the specific product configuration (e.g., with/without resolver option) of the target drive.