Output frequency over limit (_ecOUTPUT_FREQ_OVER_LIMIT)
ABB · Application Error ABB Motion Drives Error trouble shoo
What does 10041 mean?
The drive has detected that its output frequency exceeded 550 Hz. This restriction is implemented to comply with relevant European Export Control Regulations, indicating an attempt to operate beyond a regulatory limit.
Common Causes
- Commanded speed or frequency exceeding the regulatory limit of 550 Hz.
- Incorrect scaling or gear ratio parameters leading to an excessively high calculated output frequency.
- Drive parameters related to maximum frequency set above the regulatory threshold.
- External control system commanding an output frequency beyond the drive's legal limit.
Repair Steps & Checklist
Click steps to track your progress.
- 1
Review the application's speed requirements and ensure that the commanded frequency does not exceed 550 Hz.
- 2
Check drive parameters related to maximum output frequency and adjust them to be below or equal to 550 Hz.
- 3
Verify scaling factors, gear ratios, and other motion parameters to ensure accurate calculation of output frequency.
- 4
Examine the external control system (e.g., PLC, HMI) to ensure it is not issuing commands that result in exceeding the 550 Hz limit.